Appendix B: Command Quick Reference
SET COMMANDS FACTORY SETTING
S7,<1,0> - 7 bit data mode enable/disable 0= disabled
SA,<1,0> - Authentication enable/disable 0= disabled
SB,<timer> - Send BREAK Not Applicable
SC,<hex word> - Service Class 0x0000= unknown
SD,<hex word> - Device Class 0x1F00= undefined
SE,<1,0> - Encryption enable/disable 0=disabled
SF,1 - Factory Defaults
SI,<hex word> - Inquiry Scan window 0x0200
SJ,<hex word> - Page Scan window 0x0200
SL,<E,O,N> - Parity N=None
SM,<0,1,2,3,4,5> - Mode (0=Slave,1=mstr,2=trig, 3=auto, 4=DTR, 5=ANY) 0=Slave
SN,<text> - Name FireFly-xxxx
SO,<text> - Connect/Disconnect Status String NULL= no status
string
SP,<text> - Pin Code 1234
SR,<adr> - Remote Address (SR,Z to remove) NONE SET
SS,<text> - Service Name SPP
ST,<num> - Config Timer 60 seconds
SU,<rate> - Baudrate 115K
SW,<hex> - SNIFF rate 0x0000=disabled
SX,<1,0> - Bonding 0=disabled
S~,<0-4> - Profile setting 0=SPP, 1=DCE, 2=DTE, 3=MDM, 4=DUN&SPP 0 = SPP
SZ,<num> - Raw Baudrate
S?,<0,1> - Enable /Disable Role Switch 0=disabled
GET, DISPLAY COMMANDS
D - Basic Settings
E - Extended Settings
O - Other Settings
G<X> - Stored setting
H - Help
GB - BT Address
GK - Connection Status
G& - I/O Ports
V - Firmware version